MetSensor UK Get a Quote
ZPA Barometric Altimeter

ZPA Barometric Altimeter

ZPA-1 / ZPA-2

The ZPA is a barometric altimeter available in two variants, ZPA-1 using a silicon piezoresistive element and ZPA-2 using a vibrating cylinder element, both measuring atmospheric pressure and derived altitude. It is supplied in the UK by MetSensor UK.

  • Two sensing options: ZPA-1 silicon piezoresistive, ZPA-2 vibrating cylinder
  • ZPA-1 range 25-1150 hPa, ZPA-2 range 103-1450 hPa
  • ZPA-2 offers 0.1 hPa FS accuracy, equivalent to 10 cm altitude resolution
  • 0.01 hPa resolution on both models
  • RS485 output on ZPA-1; RS485/422/232 on ZPA-2
Request a quote for this product

Specifications

ZPA-1 principleSilicon piezoresistive
ZPA-1 range25-1150 hPa
ZPA-1 accuracy0.3 hPa @ 25°C
ZPA-2 principleVibrating cylinder type
ZPA-2 range103-1450 hPa
ZPA-2 accuracy0.1 hPa FS; 10 cm altitude
ZPA-2 stability<12 ppmFS
Resolution0.01 hPa (both models)
Operating voltage5-30V DC
Operating current<10 mA
Ambient temperatureZPA-1: -40 to 85°C; ZPA-2: -55 to 85°C
Ambient humidity0-100%
Data interfaceZPA-1: RS485; ZPA-2: RS485/422/232
ProtocolASCII
Power inputDC12/24V / solar
ZPA-1 Measurement accuracy0.3 hPa (25℃)
ZPA-1 Resolution0.01 hPa
ZPA-1 Data InterfaceRS485
ZPA-1 Operating voltage/current5-30V DC / <10mA
ZPA-1 Ambient temperature/humidity-40℃ to 85℃ / 0-100%
ZPA-2 Measurement accuracy0.1 hPa (FS), 10 cm
ZPA-2 Resolution0.01 hPa
ZPA-2 Stability/Repeatability<12 ppmFS
ZPA-2 Data InterfaceRS485/422/232
ZPA-2 Operating voltage/current5-30V DC / <10mA
ZPA-2 Ambient temperature/humidity-55℃ to 85℃ / 0-100%
ZPA-2 ComplianceRTCA DO160 environmental testing
General Power-InDC12/24V / Solar Power
Monitoring ParametersAtmospheric pressure/Altitude/Extended GPS output
Protocol TypeASCII

Applications

Frequently asked questions

What is the difference between ZPA-1 and ZPA-2?+

ZPA-1 uses a silicon piezoresistive sensing element with a range of 25-1150 hPa and ±0.3 hPa accuracy. ZPA-2 uses a vibrating cylinder element with a wider range of 103-1450 hPa and tighter accuracy of 0.1 hPa FS, equivalent to about 10 cm of altitude.

What resolution do the ZPA models offer?+

Both offer 0.01 hPa resolution.

What interfaces do the ZPA models support?+

ZPA-1 uses RS485. ZPA-2 supports RS485, RS422 and RS232.

What is the operating temperature range?+

ZPA-1 operates from -40°C to 85°C; ZPA-2 extends down to -55°C.